Technology Platform

Built on second near-infrared window (NIR-II) fluorescence technology, with system-level integration from light source, fluorescent microspheres to detectors, we deliver clinically-grade precision diagnostics affordable for primary care settings.

Near-Infrared II (NIR-II) Immunofluorescence Technology

WWHS pioneered the application of NIR-II fluorescence technology in the IVD (in vitro diagnostics) field, opening a new paradigm of precision diagnosis with the "golden spectral window". Built on the NIR-II technology system originally created by Prof. Hongjie Dai, we achieve full-stack system integration from light source and fluorescent microspheres to detectors, delivering clinically-grade precision diagnostics that are affordable for primary care.

  • Golden Spectral Window 1000–1700nm band: deeper tissue penetration, lower background noise, higher signal-to-noise ratio.
  • System-Level Integration Full in-house R&D of light source, fluorescent microspheres and detectors — performance and cost both under control.
  • Primary Care Affordable As easy to operate as colloidal gold tests, while delivering reliable quantitative results.
40+ Patent Applications
20+ NMPA Registrations
60+ EU CE Certifications
~100 Test Products
NIR-II vs Traditional Fluorescence Schematic

Note: FITC: Fluorescein Isothiocyanate; Cy3: Cyanine 3 Dye; Eu NPs: Europium Chelate Nanoparticles; Proteins: Proteins; VA: Vitamin A; OxiP: Fluorescent Oxidation Products; NADH: Nicotinamide Adenine Dinucleotide (Reduced); NC membrane: Nitrocellulose Membrane; Riboflavin: Riboflavin; Porphyrins/Chlorophylls: Porphyrins/Chlorophyll; Water: Water.

NIR-II Technology Principle

The differential absorption and scattering of light by biological tissue at different wavelengths determines the "readability" of a detection window. Conventional IVD relies on visible light (400–780 nm) and NIR-I (700–900 nm) bands, which suffer from significant biological autofluorescence (background noise) and tissue scattering (signal attenuation), limiting assay sensitivity and quantitative precision.

NIR-II fluorescence (1000–1700 nm) offers deeper tissue penetration, lower background noise, and higher signal-to-noise ratio compared to visible light and NIR-I. WWHS uses a proprietary encapsulation process to stably encapsulate hydrophobic NIR-II dyes inside polymer microspheres, producing monodisperse functionalized nanobeads with fluorescence quantum yield exceeding 20%. Infrared fluorescence POCT reagents based on these beads are excited at 780 nm and detected at wavelengths above 1000 nm. Compared to conventional methods, NIR-II technology delivers superior anti-interference performance, fully eliminating sample autofluorescence interference. Leveraging the strong penetration of infrared light, it enables 3D volumetric signal detection, reduces fluorescence scattering effects, and significantly boosts assay sensitivity.

  • Physical PrincipleNIR-II fluorescence imaging: deep tissue penetration, low background noise
  • Complex SamplesStable and precise quantification even with hemolytic, icteric, and lipemic samples
  • Foundational InnovationDerived from the pioneering NIR-II fluorescence imaging principle developed by Prof. Hongjie Dai's team

Three Core Technologies

NIR-II Fluorescent Nanobeads
01 / NANOBEADS

NIR-II Fluorescent Nanobeads

In-house developed infrared fluorescent nanobeads with Stokes shift > 300 nm, resistant to interference from hemolytic, icteric, and lipemic samples.

NIR-II Fluorescent Light Source
02 / LIGHT SOURCE

NIR-II Fluorescent Light Source

Custom NIR-II excitation light source eliminates biological sample background fluorescence interference, significantly improving signal clarity; line-light design delivers a physical-level performance leap.

System Integration
03 / INTEGRATION

System Integration

Light source + nanobeads + detector fully integrated, physically co-optimized — leading across the entire optical path and signal chain.

Three Core Advantages

01

Ultra-High Sensitivity

NIR-II fluorescence technology achieves pg-level detection sensitivity, meeting the needs of precision diagnosis at primary care.

02

Ultra-Stable Performance

Meets clinical assay precision requirements: low CV, excellent reproducibility, and stable batch-to-batch results.

03

Ultra-Strong Anti-Interference

Hemolytic, icteric, and lipemic samples still deliver stable results — complex samples no longer affect result interpretation.

Intellectual Property

The company has filed over 40 patent applications, including 1 granted US patent, 8 Chinese invention patents, and 9 utility model patents, building an IP barrier covering core areas such as fluorescent materials, nanobead preparation, and assay methods.

  • National LevelNational High-Tech Enterprise (certified twice)
  • Provincial / Municipal LevelShenzhen Specialized & Innovative SME · Key provincial/municipal S&T projects completed
  • Quality SystemISO13485 international quality management system certification
40+Patent Applications
1US Patents Granted
8Chinese Invention Patents
9Utility Model Patents

Nearly 100 Test ProductsCovering 12 Major Clinical Areas

Covering common and prevalent disease testing in hospitals, as well as continuous monitoring, management, and early warning for chronic disease at the primary care level.

Ecosystem Extension Growth Hormone Testing Home Testing Veterinary Testing

As simple as colloidal gold, chemiluminescence-level performance, at a cost affordable for primary care.